Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
Ebro · Data logger

EBI 12-T480

The Ebro EBI 12-T480 is a two-channel temperature data logger for process control and quality assurance in dry production processes. Its PT1000 probes connect through a screw terminal block, so a probe can be changed quickly or fixed permanently to a component during development and troubleshooting. Accuracy is up to ± 0.05 °C, the probes measure from -200 °C to +400 °C, and the logger itself works from -90 °C to +150 °C.

Range-200 °C … +400 °C
Operating temperature-90 °C … +150 °C
Accuracy± 0.05 … ± 1.5 °C
Resolution0.01 °C
SensorPT1000, class A
IP ratingIP68
Ebro EBI 12-T480 stainless steel logger with red wires to two ceramic terminal blocks for external sensors

Highlights

01
Quick-change probe connection

The PT1000 probes connect through a screw terminal block, so a probe can be changed quickly or fixed to a component.

02
Accuracy specified across full range

Accuracy is stated by band, from ± 1.5 °C at -200 °C … -90 °C to ± 0.05 °C at +120 °C … +140 °C.

03
IP68 stainless steel housing

The 316 L stainless steel and PEEK housing is rated IP68 and measures 48 mm in diameter by 24 mm in height.

04
Two measuring channels

Two PT1000 probes are logged at once, at intervals from 250 ms to 24 hours, with 2x 50,160 measurements of memory.

Parameters

T

Temperature

Range-200 °C … +400 °C
Accuracy± 0.05 … ± 1.5 °C
Resolution0.01 °C
SensorPT1000, class A
Measurement interval250 ms … 24 hours

Accuracy across the range

Accuracy over each temperature range. The bar shows where the range sits on the scale.

−200 … −90 °C± 1.5 °C
−90 … −40 °C± 0.5 °C
−40 … 0 °C± 0.2 °C
0 … +120 °C± 0.1 °C
+120 … +140 °CMost accurate± 0.05 °C
+140 … +150 °C± 0.1 °C
+150 … +250 °C± 0.5 °C
+250 … +400 °C± 0.8 °C
−200 °C−50+100+250+400 °C

Consumables

These are the consumables this instrument uses. We confirm the part numbers for your instrument when we quote.

Electrodes & spares

Replacement sensors

Electrodes, probes and replacement sensors, matched to the instrument.

Specifications

Part number1340-6633
Operating temperature-90 °C … +150 °C
Measurement range-200 °C … +400 °C
Accuracy± 1.5 °C (-200 °C … -90 °C) ± 0.5 °C (-90 °C … -40 °C) ± 0.2 °C (-40 °C … 0 °C) ± 0.1 °C (0 °C … +120 °C) ± 0.05 °C (+120 °C … +140 °C) ± 0.1 °C (+140 °C … +150 °C) ± 0.5 °C (+150 °C … +250 °C) ± 0.8 °C (+250 °C … +400 °C)
Resolution0.01 °C
Data memory2x 50,160 measurements
SensorPT1000, class A
Measuring channels2
Probe connectionScrew terminal block (luster terminal); PT1000 probe quickly replaceable
Measurement interval250 ms … 24 hours
Real-time data transmissionYes
Storage temperature-20 °C … +70 °C
Measurement modesEndless measurement; Measurement from the start time; Measure software until memory is full; Start- / Stop measurement
BatteryLithium, 3.6 V, User-replaceable
Dimensions (Ø x H)48 mm x 24 mm
WeightApprox. 90 g
Housing material316 L stainless steel / PEEK
IP ratingIP68
Factory calibration certificate-200 °C, -50 °C, 0 °C, +60 °C, +134 °C, +250 °C and +400 °C
Radio Equipment Directive (RED)2014/53/EU
Electromagnetic compatibility (EMC)DIN EN 301 489

Tags and applications

Measured variable
Temperature
Form factor
Data logger
Brand
Ebro

Downloads

Common questions

What temperature range does the Ebro EBI 12-T480 measure and operate in?

The measurement range is -200 °C … +400 °C, at a resolution of 0.01 °C. The logger operates at -90 °C … +150 °C and can be stored at -20 °C … +70 °C.

How accurate is the Ebro EBI 12-T480?

Accuracy depends on the temperature. It is ± 1.5 °C from -200 °C to -90 °C, ± 0.5 °C from -90 °C to -40 °C, ± 0.2 °C from -40 °C to 0 °C and ± 0.1 °C from 0 °C to +120 °C. It is ± 0.05 °C from +120 °C to +140 °C, ± 0.1 °C from +140 °C to +150 °C, ± 0.5 °C from +150 °C to +250 °C and ± 0.8 °C from +250 °C to +400 °C.

Can the battery in the Ebro EBI 12-T480 be replaced?

Yes. The battery is a 3.6 V lithium cell and is user-replaceable.

What is the IP rating of the Ebro EBI 12-T480?

The logger is rated IP68. The housing is 316 L stainless steel and PEEK, and it measures 48 mm in diameter by 24 mm in height. It weighs approx. 90 g.

At which temperatures is the Ebro EBI 12-T480 factory calibrated?

The factory calibration certificate covers -200 °C, -50 °C, 0 °C, +60 °C, +134 °C, +250 °C and +400 °C.

What measurement interval and memory does the Ebro EBI 12-T480 have?

The measurement interval is 250 ms … 24 hours. The data memory is 2x 50,160 measurements. The logger also supports real-time data transmission.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.