EBI 12 benchtop autoclave loggers
The Ebro EBI 12 benchtop autoclave loggers are temperature and pressure data loggers for sterilisation validation in places such as benchtop autoclaves and small steam sterilisers. They record temperature with flexible cable sensors and pressure with a piezoresistive sensor, over 0 °C to +150 °C and 1 mbar to 4,000 mbar. Readings are stored in the logger memory and can be transmitted in real time.
Highlights
One logger records temperature and pressure in benchtop autoclaves, with three flexible cable sensors of Ø1.20 mm on every version.
Measures 0 °C to +150 °C at 0.01 °C resolution, using a PT1000 class A sensor.
Measures pressure from 1 mbar to 4,000 mbar at 1 mbar resolution.
Stores 4x 20,064 measurements, with a measurement interval adjustable from 250 ms to 24 hours.
Parameters
Temperature
Pressure
Configurations
Every version is a temperature and pressure logger for benchtop autoclaves with three flexible cable sensors of Ø1.20 mm, a temperature range of 0 °C to +150 °C and IP68 protection.
EBI 12-TP451
Three flexible cable probes, 1.20 x 600 mm, Luer-Lock connection. Range 0 °C … +150 °C.
EBI 12-TP460
Three flexible cable probes, 1.20 x 600 mm. Range 0 °C … +150 °C.
EBI 12-TP453
Three flexible cable probes, 1.20 x 1,200 mm. Range 0 °C … +150 °C.
Specifications
Standards
Sterilization, steam sterilizers, medical equipment
Small steam sterilizers
Sterilization of health care products — Moist heat
Tags and applications
- Measured variable
- TemperaturePressure
- Form factor
- Data logger
- Application
- Sterilisation validation
- Brand
- Ebro
Downloads
Common questions
What temperature range and accuracy do the EBI 12 benchtop autoclave loggers have?
They measure 0 °C to +150 °C at 0.01 °C resolution. Accuracy is ±0.1 °C from 0 °C to +120 °C, ±0.05 °C from +120 °C to +140 °C and ±0.1 °C from +140 °C to +150 °C. The temperature sensor is a PT1000, class A.
What pressure range and accuracy do they have?
They measure 1 mbar to 4,000 mbar at 1 mbar resolution. On the EBI 12-TP451 and EBI 12-TP460, accuracy is ±10 mbar or ±15 mbar depending on the band up to 3,499 mbar. From 3,500 mbar to 4,000 mbar it is ±20 mbar. On the EBI 12-TP453, accuracy from 3,500 mbar to 4,000 mbar is ±0.5 % FS.
How often can the EBI 12 benchtop autoclave loggers log, and how much data do they store?
The measurement interval is 250 ms to 24 hours. Data memory is 4x 20,064 measurements. Real-time data transmission is supported.
What sensors and cable lengths do the versions have?
Every version has 3 flexible cable sensors of Ø1.20 mm, axial. The EBI 12-TP451 and EBI 12-TP460 have a cable length of 600 mm. The EBI 12-TP453 has a needle length of 1,200 mm. The EBI 12-TP451 also has a Luer-Lock.
Which sterilisation standards do the EBI 12 benchtop autoclave loggers relate to?
The standards listed are EN 285 for steam sterilisers in medical equipment, EN 13060 for small steam sterilisers and ISO 17665 for moist heat sterilisation of health care products.
At which points is the factory calibration certificate issued?
Temperature is certified at 0 °C, +60 °C and +134 °C. Pressure is certified at 100 mbar and 3,100 mbar at +25 °C, and at 3,100 mbar at +134 °C.
Tell us what you need to measure.
Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.