Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
Ebro · Data logger

EBI 11 temperature and pressure loggers

The Ebro EBI 11-TP210 and EBI 11-P111 are miniature data loggers that record temperature and pressure: the EBI 11-TP210 inside bottles, for pasteurisation control and sparkling wine production, and the EBI 11-P111 during validation of small sterilisers and cassette autoclaves. The EBI 11-TP210 fits most commercially available bottles with an optional bottle adapter, and the EBI 11-P111 connects by Luer lock. Pressure readings are temperature compensated, and the loggers are programmed and read out through an Ebro interface with Winlog.pro software.

Temperature range0 °C … +150 °Cvaries by version
Pressure range1 mbar … 10,000 mbarvaries by version
Temperature accuracy± 0.1 °Cvaries by version
Pressure accuracyfrom ± 15 mbarvaries by version
Data memory2x 7,500 Measurement values
IP ratingIP68
EBI 11-P111: Polished stainless steel ebro logger with a connector fitting on top

Highlights

01
Temperature and pressure inside bottles

Every version is a miniature logger that measures temperature and pressure inside a bottle, in a housing of Ø 16.5 mm by 48 mm.

02
Temperature-compensated pressure readings

Pressure measurements are temperature compensated over the complete range, on every version.

03
IP68 stainless-steel housing

The housing is 316 TI stainless steel, rated IP68, and weighs approx. 45 g.

04
Adjustable interval and start modes

The measurement interval runs from 1 s to 24 h, with endless, start-time, start-immediately and start/stop measurement modes.

Parameters

T

Temperature

Range0 °C … +150 °C
Accuracy± 0.1 °C
Resolution0.01 °C
p

Pressure

Pressure range and accuracy depend on the version, and the accuracy also varies with the pressure band being measured.

Range1 mbar … 10,000 mbar
Accuracy± 20 … ± 40 mbar
Resolution1 mbar

Configurations

Every version is a stainless-steel temperature and pressure logger with a Pt 1000 Class A sensor, IP68 housing, the same storage capacity and the same measurement interval range.

1340-6265

EBI 11-TP210

For pasteurization control; 0 °C … +140 °C; 1 mbar … 8,000 mbar; M5 thread-connection.

1340-6296

EBI 11-P111

For mini validation; 0 °C … +150 °C; 1 mbar … 10,000 mbar; Luerlock connection; ISO 17665 and ISO 15883.

Specifications

Operating temperatureEBI 11-TP2100 °C … +140 °CEBI 11-P1110 °C … +150 °C
Measuring range, temperatureEBI 11-TP2100 °C … +140 °CEBI 11-P1110 °C … +150 °C
Measuring range, pressureEBI 11-TP2101 mbar … 8,000 mbarEBI 11-P1111 mbar … 10,000 mbar
Accuracy, temperatureEBI 11-TP210±0.1 °C (0 °C … +140 °C)EBI 11-P111±0.1 °C (0 °C … +150 °C)
Accuracy, pressureEBI 11-TP210±20 mbar (0 … 4,000 mbar) ±40 mbar (4,000 mbar … 8,000 mbar)EBI 11-P111±15 mbar (0 … 4,000 mbar) ±20 mbar (4,000 mbar … 6,000 mbar) ±0.5 % of the measured value (6,000 mbar … 10,000 mbar)
Resolution, temperature0.01 °C
Resolution, pressure1 mbar
Storage capacity2x 7,500 Measurement values
SensorPt 1000, Class A
Measurement interval1 s … 24 h
Storage temperature-20 °C … +70 °C
Measurement modeendless measurement; Measure upon starttime; Start immediately until end of memory; Start- / Stop measurement
BatteryLithium, 2x BR1225A, 3 V, user-replaceable
Dimensions(Ø x H) 16.5 mm x 48 mm
WeightApprox. 45 g
Housing material316 TI stainless-steel
IP ratingIP68
Factory calibration certificate0 °C, +60 °C and +134 °C; 100 mbar, 3,100 mbar, 6,000 mbar at +25 °C and 3,100 mbar at +134 °C
ConnectionEBI 11-TP210M5 thread-connectionEBI 11-P111Luerlock
Food contact materials (FCM)EBI 11-TP210EN 1935/2004EBI 11-P111(EC) 1935/2004
EMC directive2014/30/EU
ISO 17665Sterilization of health care products — Moist heat
ISO 15883Washer Disinfectors

Tags and applications

Measured variable
TemperaturePressure
Form factor
Data logger
Brand
Ebro

Downloads

Common questions

What temperature and pressure range does the EBI 11 cover?

The EBI 11-TP210 measures 0 °C to +140 °C and 1 mbar to 8,000 mbar. The EBI 11-P111 measures 0 °C to +150 °C and 1 mbar to 10,000 mbar.

Will the EBI 11-TP210 fit inside a bottle?

The EBI 11-TP210 measures Ø 16.5 mm by 48 mm and fits most commercially available bottles. An optional bottle adapter positions it.

How many measurement values can the EBI 11 store?

Storage capacity is 2x 7,500 measurement values.

What measurement interval can I set on the EBI 11?

The interval is adjustable from 1 s to 24 h. The measurement modes are endless measurement, measure upon start time, start immediately until end of memory, and start/stop measurement.

Can the battery in the EBI 11 be replaced?

Yes. It takes two BR1225A 3 V lithium batteries, and the user can replace them. The AL 113 battery exchange set has 6 batteries, 3 gaskets with lubricant and a screwdriver. The AL 113L set covers 10 battery changes, with 20 batteries, 10 O-rings with grease and a changing tool.

Does the EBI 11-P111 refer to ISO 17665 and ISO 15883?

Yes. Its datasheet lists ISO 17665, sterilization of health care products by moist heat, and ISO 15883 for washer disinfectors.

What do I need to program and read out the loggers?

An Ebro interface set with Winlog.pro software, connected by USB. The SI 1100 set has a 2-port IF 100 interface and the SI 1300 set a 4-port IF 300 interface. The SK 6100 starter kit contains an EBI 11-T210, an IF 300 interface and Winlog.pro, and takes further EBI 11 loggers.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.