Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
Ebro · Data logger

EBI 12-T103

The Ebro EBI 12-T103 is a versatile temperature data logger for independent routine checks in medicine, care facilities and production, such as qualifying warehouses and refrigeration equipment or monitoring dry ice transport. It measures from -82 °C to +150 °C with a PT1000 class A sensor and can be sterilised. The EBI 12-T103-EX is ATEX approved for explosive areas and transmits readings in real time.

Range-82 °C … +150 °C
Accuracy± 0.05 … ± 0.5 °C
Resolution0.01 °C
Data memory100,320 measurements
IP ratingIP68
ebro logger stainless steel housing on a white surface

Highlights

01
PT1000 temperature data logger

Every version records temperature with a PT1000 Class A sensor over a range of -82 °C to +150 °C.

02
Accuracy stated by temperature band

± 0.05 °C from +120 °C to +140 °C, ± 0.1 °C from 0 °C to +120 °C, and ± 0.5 °C below -40 °C.

03
IP68 stainless steel housing

The housing is 316 L stainless steel and PEEK, rated IP68, and measures 48 mm in diameter by 24 mm in height.

04
Logging intervals and memory capacity

The measurement interval runs from 250 ms to 24 hours. Memory holds 100,320 measurements.

Parameters

T

Temperature

Range-82 °C … +150 °C
Accuracy± 0.05 … ± 0.5 °C
Resolution0.01 °C
SensorPT1000, Class A

Accuracy across the range

Accuracy over each temperature range. The bar shows where the range sits on the scale.

−82 … −40 °C± 0.5 °C
−40 … 0 °C± 0.2 °C
0 … +120 °C± 0.1 °C
+120 … +140 °CMost accurate± 0.05 °C
+140 … +150 °C± 0.1 °C
−82 °C−24+34+92+150 °C

Configurations

Every version has the PT1000 Class A sensor, the -82 °C … +150 °C measurement range, 0.01 °C resolution, storage for 100,320 measurements and a 316 L stainless steel and PEEK housing, and the versions differ in ATEX approval and real-time data transmission.

1340-6690-0100

EBI 12-T103

Range -82 °C … +150 °C.

1340-6690-EX

EBI 12-T103-EX

Range -82 °C … +150 °C. ATEX approved for explosive areas, -40 °C … +85 °C there. Real-time data transmission.

Specifications

Operating temperature-90 °C … +150 °C
Measurement range-82 °C … +150 °C
Accuracy± 0.5 °C (-82 °C … -40 °C) ± 0.2 °C (-40 °C … 0 °C) ± 0.1 °C (0 °C … +120 °C) ± 0.05 °C (+120 °C … +140 °C) ± 0.1 °C (+140 °C … +150 °C)
Resolution0.01 °C
Storage capacity100,320 measurements
SensorPT1000, Class A
Measurement interval250 ms … 24 hours
Real-time data transmissionEBI 12-T103NoEBI 12-T103-EXYes
Storage temperature-20 °C … +70 °C
Measurement modesEndless measurement; Measure upon start time; Start immediately until end of memory; Start- / Stop measurement
BatteryLithium, 3.6 V, User-replaceable
Dimensions (Ø x H)48 mm x 24 mm
Weightapp. 90 g
Housing material316 L stainless steel / PEEK
IP ratingIP68
Factory calibration certificate-20 °C, 0 °C, +60 °C and +134 °C
Washer disinfector standardISO 15883
Radio equipment directive (RED)2014/53/EU
Food material contactFCM EN 1935/2004
Electromagnetic compatibility (EMC)DIN EN 301 489
ATEX approvedYes
Permissible ambient conditions in the hazardous area-40 °C … +85 °C; 100 Pa … 400 kPa
ATEX directive2014/34/EU
ATEX-TypeII1G Ex ia IIC T4 Ga

Standards

ISO 15883

Washer Disinfectors

Tags and applications

Measured variable
Temperature
Form factor
Data logger
Brand
Ebro

Downloads

Common questions

What temperature range does the EBI 12-T103 measure?

It measures from -82 °C to +150 °C with a resolution of 0.01 °C. The sensor is a PT1000, Class A.

What is the EBI 12-T103 accuracy at 134 °C?

Accuracy is ± 0.05 °C between +120 °C and +140 °C. The factory calibration certificate covers -20 °C, 0 °C, +60 °C and +134 °C.

Can the EBI 12-T103 be used in washer disinfectors?

ISO 15883, the washer disinfector standard, is listed for this logger. The housing is 316 L stainless steel and PEEK, and the IP rating is IP68.

Is the EBI 12-T103 ATEX approved?

The EBI 12-T103-EX version is ATEX approved. Its type is II1G Ex ia IIC T4 Ga under directive 2014/34/EU. The permissible ambient conditions in the hazardous area are -40 °C to +85 °C and 100 Pa to 400 kPa.

Does the EBI 12-T103 transmit data in real time?

The EBI 12-T103 does not. The EBI 12-T103-EX does.

What battery does the EBI 12-T103 use and how many readings can it store?

It uses a 3.6 V lithium battery that the user can replace. It stores 100,320 measurements.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.