Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
Ebro · Data logger

EBI 12 pasteurisation loggers (bottles)

The Ebro EBI 12 pasteurisation loggers (bottles) are single-channel temperature data loggers for recording temperature in bottle pasteurisation and other food safety and HACCP work. A PT1000 class A sensor on a rigid probe measures from -55 °C to +140 °C, and the logger stores readings in its internal memory at an interval you set. Every version is the same logger and differs only in probe length, and each probe has an M10 thread.

Range-55 °C … +140 °C
Accuracy± 0.3 … ± 0.8 °C
Resolution0.01 °C
Data memory27,840 measurements
IP ratingIP68
EBI 12-T263: Stainless steel threaded stand or holder with a round base and rod

Highlights

01
Temperature logger with rigid probes

Records temperature on one channel with a PT1000 class A sensor. Every version has a rigid 6 mm probe with M10 thread.

02
Accuracy stated by temperature range

± 0.3 °C from -40 °C to +140 °C and ± 0.8 °C from -55 °C to -40 °C, at 0.01 °C resolution.

03
IP68 stainless steel housing

The housing is 316 L stainless steel and PEEK, protection class IP68, 48 mm in diameter by 24 mm in height.

04
Measurement modes and intervals

Endless measurement, measure upon start time, start until end of memory, and start/stop measurement, with intervals from 1 s to 24 hours.

Parameters

T

Temperature

Range-55 °C … +140 °C
Accuracy± 0.3 … ± 0.8 °C
Resolution0.01 °C
SensorPT1000, class A

Accuracy across the range

Accuracy over each temperature range. The bar shows where the range sits on the scale.

−55 … −40 °C± 0.8 °C
−40 … +140 °CMost accurate± 0.3 °C
−55 °C−6.25+42.5+91.25+140 °C

Configurations

Every version shares the -55 °C to +140 °C range, the PT1000 class A sensor, the 27,840-measurement memory, the IP68 housing and the 6 mm rigid probe with M10 thread, and the versions differ only in probe length.

1340-6618

EBI 12-T261

Rigid probe, 6 x 135 mm, M10 thread.

1340-6619

EBI 12-T262

Rigid probe, 6 x 190 mm, M10 thread.

1340-6620

EBI 12-T263

Rigid probe, 6 x 245 mm, M10 thread.

1340-6621

EBI 12-T264

Rigid probe, 6 x 270 mm, M10 thread.

1340-6622

EBI 12-T265

Rigid probe, 6 x 300 mm, M10 thread.

Specifications

Operating temperature-55 °C … +140 °C
Measurement range-55 °C … +140 °C
Accuracy± 0.8 °C (-55 °C … -40 °C) ± 0.3 °C (-40 °C … +140 °C)
Resolution0.01 °C
Data memory27,840 measurements
SensorPT1000, class A
Measurement interval1 s … 24 hours
Real-time data transmissionNo
Storage temperature-20 °C … +70 °C
Measurement modesendless measurement; Measure upon starttime; Start immediately until end of memory; Start- / Stop measurement
BatteryLithium, 3.6 V, User-replaceable
Dimensions (Ø x H)48 mm x 24 mm
WeightApp. 90 g
Housing material316 L stainless steel / PEEK
Protection classIP68
Factory calibration certificate-20 °C, 0 °C, +60 °C and +121 °C
Food material contactFCM EN 1935/2004
Radio equipment directive2014/53/EU (RED)
Electromagnetic compatibility (EMC)DIN EN 301 489
Measuring channels1
Probe threadM10
Probe lengthEBI 12-T261L = 135 mmEBI 12-T262L = 190 mmEBI 12-T263L = 245 mmEBI 12-T264L = 270 mmEBI 12-T265L = 300 mm
Temperature sensor size6 mm, rigid

Tags and applications

Measured variable
Temperature
Form factor
Data logger
Brand
Ebro

Downloads

Common questions

What temperature range and accuracy do the EBI 12 pasteurisation loggers (bottles) have?

The measurement range is -55 °C to +140 °C. Accuracy is ± 0.3 °C from -40 °C to +140 °C and ± 0.8 °C from -55 °C to -40 °C. Resolution is 0.01 °C. The sensor is a PT1000, class A.

How many measurements can the EBI 12 pasteurisation loggers (bottles) store?

The data memory holds 27,840 measurements. The measurement interval can be set from 1 s to 24 hours.

Do the EBI 12 pasteurisation loggers (bottles) transmit data in real time?

No. They do not offer real-time data transmission. Measurements are stored in the data memory.

Can the battery be replaced?

Yes. The logger uses a 3.6 V lithium battery that the user can replace.

Which temperatures does the factory calibration certificate cover?

The factory calibration certificate covers -20 °C, 0 °C, +60 °C and +121 °C.

What is the protection class and housing material?

The protection class is IP68. The housing is 316 L stainless steel and PEEK. The logger is listed for food material contact under FCM EN 1935/2004.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.