EBI 12 food loggers
The Ebro EBI 12 food loggers are two-channel needle-probe temperature data loggers for food safety and HACCP work, including recording temperature inside a container and outside it. The axial probe measures inside the container and the side sensor measures outside it, and the logger stores the readings in its own memory. The PT1000 class A sensor covers -55 °C to +150 °C, and the versions differ in the length of the axial probe.
Highlights
A PT1000 class A logger with an axial probe inside the container and a side sensor outside it, in a choice of probe lengths.
Range is -55 °C to +150 °C at 0.01 °C resolution. Accuracy is ± 0.1 °C from 0 °C to +150 °C.
The housing is 316 L stainless steel and PEEK, rated IP68. Food material contact is stated to FCM EN 1935/2004.
The measurement interval runs from 1 s to 24 hours. Data memory is 2x 13,920 measurements, with four measurement modes.
Parameters
Temperature
Accuracy across the range
Accuracy over each temperature range. The bar shows where the range sits on the scale.
Configurations
Every version of the EBI 12 food loggers has the same PT1000 class A sensor, 6 mm probe diameter, measurement range, accuracy, data memory and side sensor outside the container, and the versions differ only in the length of the axial probe that goes inside it.
EBI 12-T461
Axial probe, 6 x 135 mm, inside the container. Side sensor outside it.
EBI 12-T462
Axial probe, 6 x 190 mm, inside the container. Side sensor outside it.
EBI 12-T463
Axial probe, 6 x 245 mm, inside the container. Side sensor outside it.
EBI 12-T464
Axial probe, 6 x 270 mm, inside the container. Side sensor outside it.
EBI 12-T465
Axial probe, 6 x 300 mm, inside the container. Side sensor outside it.
Specifications
Tags and applications
- Measured variable
- Temperature
- Form factor
- Data logger
- Application
- Food safety & HACCP
- Brand
- Ebro
Downloads
Common questions
What temperature range do the EBI 12 food loggers measure?
They measure from -55 °C to +150 °C with a resolution of 0.01 °C. The sensor is a PT1000, class A.
How accurate are the EBI 12 food loggers?
Accuracy is ± 0.5 °C from -55 °C to -40 °C, ± 0.2 °C from -40 °C to 0 °C and ± 0.1 °C from 0 °C to +150 °C.
What probe lengths do the EBI 12 food loggers come with?
The axial probe is 6 mm in diameter. The length depends on the version: 135 mm for the EBI 12-T461, 190 mm for the EBI 12-T462, 245 mm for the EBI 12-T463, 270 mm for the EBI 12-T464 and 300 mm for the EBI 12-T465. The axial probe sits inside the container and the side sensor sits outside it.
Do the EBI 12 food loggers send data in real time?
No. They record to internal memory, which holds 2x 13,920 measurements.
Can I replace the battery in the EBI 12 food loggers myself?
Yes. The battery is a 3.6 V lithium cell and the user can replace it.
What measurement interval can I set on the EBI 12 food loggers?
The interval can be set from 1 s to 24 hours.
Tell us what you need to measure.
Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.






