Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
WTW · Portable dissolved oxygen meter

ProfiLine Oxi 3205 / Oxi 3310

The WTW ProfiLine Oxi 3205 and Oxi 3310 are portable dissolved oxygen meters for work in places such as surface waters, wastewater treatment plants and fish farming. They read galvanic CellOx and DurOx sensors and show results as saturation or concentration, with salinity compensation for sea water. The Oxi 3310 also logs data at set intervals over a mini USB interface and can be calibrated against an external standard such as Winkler titration.

Dissolved oxygen concentration0.00…20.00 mg/l, 0…90 mg/L
Dissolved oxygen saturation0.0…200.0 %, 0…600 %
Partial pressure0…200.0 hPa, 0…1250 hPa
Temperature−5.0…50.0 °C
IP ratingIP 67
Oxi 3310: Oxi 3310 handheld meter front view with extended keypad and display reading 7.87 mg/l

Highlights

01
Oxygen concentration and saturation

Both models measure dissolved oxygen as concentration and saturation, with temperature.

02
Galvanic CellOx and DurOx sensors

Both meters work with galvanic oxygen sensors of the CellOx and DurOx series, except StirrOx.

03
Barometer and salinity compensation built in

A built-in barometric sensor is fitted, and salinity compensation is adjustable for readings in sea water.

04
Waterproof IP 67 meter, backlit display

Rated IP 67, with a backlit graphic display, and powered by four AA batteries or four NiMH rechargeable batteries.

Parameters

O₂

Dissolved oxygen concentration

Range0.00…20.00 mg/l; 0…90 mg/L
Accuracy± 0.5 %
O₂ %

Dissolved oxygen saturation

Range0.0…200.0 %; 0…600 %
Accuracy± 0.5 %
pO₂

Partial pressure

Range0…200.0 hPa; 0…1250 hPa
Accuracy± 0.5 %
T

Temperature

Range−5.0…50.0 °C
Accuracy± 0.1 °C

Configurations

Both models measure dissolved oxygen with galvanic CellOx or DurOx sensors, are rated IP 67 and run on AA or NiMH batteries.

2BA100

Oxi 3205

Backlit LCD graphic display and calibration in calibration vessels; runs 100 hours with the backlight on.

2BA300

Oxi 3310

A data logger with 200 manual or 5000 automatic records, a USB interface, 10 stored calibrations and calibration against an external standard.

Consumables

These are the consumables this instrument uses. We confirm the part numbers for your instrument when we quote.

Standards & buffers

Buffers & electrolytes

Calibration standards, pH buffers and electrolyte solutions for calibrating the instrument.

Electrodes & spares

Electrodes & probes

Electrodes, probes and replacement sensors, matched to the instrument.

Specifications

Value tolerance±1 digit
Calibration memoryOxi 3205current calibrationOxi 3310up to 10 calibrations
AutoReadOxi 3205automaticOxi 3310automatic/manual selectable
DisplayLCD graphic display, backlit
Data memoryOxi 3310manual 200/5000 automatic
LoggerOxi 3310manual/time controlled
InterfaceOxi 3310USB 1.1
Power supply4 x 1.5 V AA or 4 x 1.2 V NiMH rechargeable battery
Continuous operation timeOxi 3205100 hours with backlitOxi 3310up to 100 hours/800 hours w/o backlit
IP ratingIP 67
Dissolved oxygen concentration0.00…20.00 mg/l ±0.5 % of val. 0…90 mg/L ±0.5 % of val.
Dissolved oxygen saturation0.0…200.0 % ±0.5 % of val. 0…600 % ±0.5 % of val.
Partial pressure0…200.0 hPa, 0…1250 hPa ±0.5 % of val.
Temperature−5.0…50.0 °C ±0.1 °C
CalibrationOxi 3205CellOx®/DurOx® with calibration vesselsOxi 3310CellOx®/DurOx® with calibration vessels versus external standard
Built-in barometric sensoryes

Tags and applications

Brand
WTW

Downloads

Common questions

Which oxygen sensors work with the Oxi 3205 and Oxi 3310?

Both meters work with galvanic oxygen sensors of the CellOx and DurOx series. StirrOx sensors are not supported.

Can it compensate for salinity in sea water?

Yes. Salinity compensation is adjustable, so readings in sea water can be corrected.

Does the Oxi 3205 have a data logger or USB interface?

No. The Oxi 3205 has no data memory, logger or interface. The Oxi 3310 has a manual or time-controlled logger, with memory for 200 manual or 5000 automatic records, and a USB 1.1 interface.

Can the Oxi 3310 be calibrated against an external standard?

Yes. It can be calibrated against external standards such as reference sensors or Winkler titration, and it stores up to 10 calibrations.

How is the meter powered and how long does it run?

It takes four 1.5 V AA batteries or four 1.2 V NiMH rechargeable batteries. The Oxi 3205 runs for 100 hours with the backlight on. The Oxi 3310 runs for up to 100 hours, or 800 hours without the backlight.

What is the accuracy for dissolved oxygen and temperature?

Dissolved oxygen concentration, saturation and partial pressure are each ±0.5 % of value, and temperature is ±0.1 °C, with a value tolerance of ±1 digit.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.