inoLab Oxi 7310

The WTW inoLab Oxi 7310 is a benchtop dissolved oxygen meter for environmental work such as BOD measurement and for industrial applications including pharmaceutical research, beverage and food. It works with a galvanic oxygen sensor chosen to suit the task: the universal CellOx 325, the self-stirring StirrOx G for BOD measurements, or the DurOx 325 for training. It reports concentration, saturation, partial pressure and temperature, compensates for air pressure automatically and corrects for salinity in samples with salt content.

Dissolved oxygen concentration0.00 … 20.00 mg/l; 0 … 90 mg/l
Dissolved oxygen saturation0.0 … 200.0 %; 0 … 600 %
Partial pressure0 … 200.0 hPa, 0 … 1250 hPa
Temperature0.0 … 50.0 °C
InterfaceMini USB-B
Oxi 7310: inoLab Oxi 7310 benchtop meter seen straight from the front, showing the display and keypad

Highlights

01
Choice of galvanic oxygen sensors

Supports the universal CellOx 325, the self-stirring StirrOx G for BOD measurements, and the DurOx 325 for training.

02
Air pressure and salinity correction

Air pressure compensation is automatic and uses a built-in pressure sensor. Salinity correction is built in for samples with salt content.

03
Automatic GLP/AQA documentation of results

Measurements are documented according to GLP/AQA, with the sensor's serial number saved. The meter stores 10 calibration records.

04
Memory and USB data output

The memory holds 500 manual or 5000 automatic entries. Data leaves the meter through the Mini USB-B interface.

Parameters

O₂

Dissolved oxygen concentration

The concentration range and accuracy depend on the D.O. sensor connected.

Range0.00 … 20.00 mg/l; 0 … 90 mg/l
Accuracy± 0.5 %
O₂ sat.

Dissolved oxygen saturation

The saturation range and accuracy depend on the D.O. sensor connected.

Range0.0 … 200.0 %; 0 … 600 %
Accuracy± 0.5 %
pO₂

Oxygen partial pressure

The partial pressure range and accuracy depend on the D.O. sensor connected.

Range0 … 200.0 hPa, 0 … 1250 hPa
Accuracy± 0.5 %
T

Temperature

Range0.0 … 50.0 °C
Accuracy± 0.1 °C

Consumables

These are the consumables this instrument uses. We confirm the part numbers for your instrument when we quote.

Standards & buffers

Buffers & electrolytes

Calibration standards, pH buffers and electrolyte solutions for calibrating the instrument.

Electrodes & spares

Electrodes & probes, Replacement sensors

Electrodes, probes and replacement sensors, matched to the instrument.

Specifications

Part number1BA300
Temperature compensationAutomatic
Calibration points1
Calibration records10
Calibration timerYes
Memory entries500/5000 (manual/automatic)
InterfaceMini USB-B
GLP/AQA supportingYes
DisplayBacklit b/w graphic
Printer optionYes
AdditionalInput serial number of sensor
Power supplyBattery or universal power supply
Dissolved oxygen concentration0.00 … 20.00 mg/l ±0.5 % of value; 0 … 90 mg/l ±0.5 % (depends on D.O. sensor)
Dissolved oxygen saturation0.0 … 200.0 % ±0.5 % of value; 0 … 600 % ±0.5 % of value (depends on D.O. sensor)
Partial pressure0 … 200.0 hPa, 0 … 1250 hPa ±0.5 % of value (depends on D.O. sensor)
Temperature0.0 … 50.0 °C ±0.1 °C
Built-in pressure sensorYes
Printed paper readabilityUp to 7 years
Selectable oxygen sensors3

Tags and applications

Deployment
Laboratory
Brand
WTW

Downloads

Common questions

What does the inoLab Oxi 7310 measure?

It measures dissolved oxygen concentration, oxygen saturation, oxygen partial pressure and temperature. Concentration is given up to 20.00 mg/l, or up to 90 mg/l depending on the D.O. sensor.

Which oxygen sensors work with the Oxi 7310?

Three galvanic sensors can be selected: the universal CellOx 325, the self-stirring StirrOx G for BOD measurements, and the DurOx 325 for training.

Can the Oxi 7310 be used for BOD measurements?

Yes. The StirrOx G is the self-stirring galvanic sensor intended for BOD measurements, and the meter lists BOD among its applications.

Does the Oxi 7310 correct for air pressure and salinity?

Yes. Air pressure compensation is automatic with a built-in pressure sensor, and salinity correction is built in for samples with salt content.

How do I get data out of the Oxi 7310?

Data is output through the Mini USB-B interface. A built-in printer is available as an option, and the meter also stores 500 manual or 5000 automatic entries.

Can the Oxi 7310 run on batteries?

Yes. It is powered either by battery or by the universal power supply.