EBI 300
The Ebro EBI 300 is a USB PDF data logger for recording temperature, and relative humidity on the EBI 300 TH, in places such as cold rooms, warehouses and transport. Plug it into a PC's USB port and it creates a PDF report of the readings, with no special software needed. It is classified to EN 12830 for storage and transport of food, and the EBI 300 TE adds an external probe for core temperatures.

Highlights
Plug the logger into a PC's USB port and it writes a PDF report of the readings. No special software is needed to read it.
The EBI 300 logs with its internal sensor. The TE adds a probe for core temperatures, and the TH adds relative humidity.
The TE and TH probes connect through a digital interface. Send a probe away for calibration and connect a replacement.
Suitability S (storage) and T (transport), location C, accuracy class 1. Yearly inspection per EN 13486.
Parameters
Temperature
Relative humidity (EBI 300 TH)
Measured by a capacitive sensor in the external probe.
Configurations
All three store 40,000 readings at intervals from 1 minute to 24 hours, in a polycarbonate housing with a replaceable CR 2450 battery.
EBI 300
Internal NTC sensor, -30 to +70 °C. IP65.
EBI 300 TE
Adds an external NTC probe on a 1 m cable, -35 to +70 °C, for core temperatures. IP65.
EBI 300 TH
Adds an external probe for relative humidity, 0 to 100 %, and temperature. IP20.
Specifications
Standards
Temperature recorders for storage and transport of food. Suitability S (storage) and T (transport), location C (food storage and distribution systems), accuracy class 1. Yearly inspection per EN 13486.
Tags and applications
Select any tag to see every other instrument that carries it. A tag with no link is one this line does not filter on.
Downloads
Common questions
What temperature range does each version cover?
The EBI 300 and the EBI 300 TH cover -30 °C to +70 °C. The EBI 300 TE probe covers -35 °C to +70 °C. Resolution is 0.1 °C.
How accurate is it?
Temperature is ±0.5 °C from -20 °C to +40 °C. Outside that it is ±0.8 °C, or ±1.0 °C on the EBI 300 TH probe.
Which version measures humidity?
The EBI 300 TH. It measures 0 to 100 % rH, to ±3 % rH between 10 and 90 % rH at 25 °C.
Is software needed to read it?
No. Connecting it to a PC by USB creates a PDF report. Winlog.basic or Winlog.pro software can process the readings further.
Can the external probes be replaced?
Yes. The TPC 300 (1341-6331) replaces the EBI 300 TE probe, and the TPH 400 (1341-6336) replaces the EBI 300 TH probe.
How many readings can it store?
40,000 readings, at intervals from 1 minute to 24 hours.
Does it comply with EN 12830?
Yes. It is classed S (storage) and T (transport), location C (food storage and distribution systems), accuracy class 1. Yearly inspection per EN 13486 applies.
How long does the battery last?
Up to 2 years, depending on the application. It takes a CR 2450 lithium button cell.
Tell us what you need to measure.
Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.