Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
Lovibond · Portable pH/ORP meter

SD 305 pH/ORP

The Lovibond SD 305 pH/ORP is a waterproof hand-held pH, redox and temperature meter for on-site water analysis in places such as swimming pools and cooling towers. It stores readings in a manual or automatic data logger and connects to a PC by USB. Temperature compensation is automatic, and calibration can use automatic buffer detection.

pH measuring range-2 - 16
Redox measuring range-2000 - 2000 mV
Temperature measuring range-5 - 150 °C
IP ratingIP 67
Battery life500 h
SD 305 pH/ORP handheld meter seen from the front with blank display and keypad

Highlights

01
Hand-held pH, redox, temperature meter

One meter measures pH, redox and temperature. It has protective armouring and a rear stand that also works as a hanger or belt clip.

02
Manual and automatic data logging

The manual logger stores 1000 data sets. The automatic logger stores 10000 data sets at intervals of 1 to 3600 s.

03
Automatic or manual calibration

Calibration uses 1-, 2- or 3-point procedures, either automatic or manual, with automatic buffer detection.

04
USB interface and battery power

The meter connects to a PC by USB. It runs on two AAA batteries rated for 500 h, or on micro-USB power.

Parameters

pH

pH

Range-2 - 16
Resolution0.001 pH
ORP

Redox

Range-2000 - 2000 mV
Resolution0.1 mV
T

Temperature

Range-5 - 150 °C

Configurations

Every configuration includes the same instrument in protective armouring with electrode holder, batteries, instruction manual and warranty information.

724630

SD 305 pH/ORP

Instrument in protective armouring with electrode holder and batteries.

724640

SD 305 pH/ORP Set 1

Instrument with pH/temp. plastic electrode type 231, pH buffer set and storage solution, in case.

724641

SD 305 pH/ORP Set 2

Instrument with pH electrode type 226, PT 1000 temperature sensor, pH buffer set and storage solution, in case.

724642

SD 305 pH/ORP Set 3

Instrument with redox electrode type 242 (BNC plug), PT 1000 temperature sensor, 470 mV redox standard and storage solution, in case.

Consumables

These are the consumables this instrument uses. We confirm the part numbers for your instrument when we quote.

Standards & buffers

Buffers & electrolytes, Calibration standards

Calibration standards, pH buffers and electrolyte solutions for calibrating the instrument.

Electrodes & spares

Electrodes & probes

Electrodes, probes and replacement sensors, matched to the instrument.

Specifications

DisplayBacklit LCD
InterfacesUSB
Data loggerManual Logger: 1000 data sets (single value by keystroke). Auto. Logger: 10000 data sets (cyclic, time interval: 1 - 3600 s)
Auto-OFFYes
CalibrationAutomatic or manual 1-, 2- or 3-point calibration
Power supply2 AAA batteries Micro-USB
Battery life500 h
PortabilityPortable
Temperature compensationAutomatic
IP ratingIP 67
ComplianceCE
Dimensions128 x 164 x 37 mm
Weight287 g
Delivery scopeEvery set: Instrument in protective armouring including electrode holder; Batteries; Instruction manual; Warranty information. By set: case and storage Solution for pH/ORP (Set 1, Set 2, Set 3); pH-buffer-set (pH 4.01/7.00/10.01) (Set 1, Set 2); pH/temp. plastic-electrode type 231 (order code 721231) (Set 1); pH electrode type 226 (order code 721226) and temperature sensor PT 1000 (order code 721246) (Set 2); temperature sensor PT 1000, redox electrode, plastic/gel, type 242, BNC-plug (order code 721242BNC) and redox Standard Solution 470 mV (Set 3).
Resolution0.001 pH / 0.1 mV

Tags and applications

Parameter
pH & ORP

Downloads

Common questions

What does the Lovibond SD 305 pH/ORP measure?

It measures pH from -2 to 16, redox from -2000 to 2000 mV and temperature from -5 to 150 °C. Temperature compensation is automatic.

Is the SD 305 waterproof?

Yes. The meter has an IP 67 rating and is supplied in protective armouring.

How many readings can the SD 305 store?

The manual logger stores 1000 data sets, one value per keystroke. The automatic logger stores 10000 data sets at a time interval of 1 to 3600 s.

How do I connect the SD 305 to a PC?

The meter has a USB interface for connection to a PC.

What power does the SD 305 use?

It takes two AAA batteries, with a battery life of 500 h, or micro-USB power. The meter also has an auto-off function.

How is the SD 305 calibrated?

Calibration is automatic or manual, with 1-, 2- or 3-point procedures. The meter detects buffers automatically.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.