Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
WTW · Portable pH and conductivity meter

ProfiLine pH/Cond 3320

The WTW ProfiLine pH/Cond 3320 is a portable multi-parameter meter for pH, mV, ISE and conductivity measurement in process work such as chemical, life science and pharmaceutical production, including pH and conductivity measurement according to pharmacopoeia. Its two inputs take a pH, mV or ISE electrode and a conductivity cell at the same time, and the backlit two-channel graphic display shows both values in parallel. The data logger stores each record with date, time and an assignable ID number, and the waterproof USB interface transfers the data.

pH range−2.000…19.999 pH
mV range±1200.0 mV / ±(2500 ±1) mV
ISE range0.000…999999, 4 ranges (mg/l, µmol/l, mg/kg, ppm, %)
Temperature range−5.0…105.0 °C
Logging interval1 s … 60 minutes
IP ratingIP 67
pH/Cond 3320: ProfiLine pH/Cond 3320 handheld meter seen from the front with display showing pH and conductivity readings and three sensor cables attached

Highlights

01
Two inputs, measured simultaneously

One input takes pH, mV or ISE electrodes and the other a conductivity cell, so both are measured at the same time.

02
Logger with GLP-supporting records

Records carry date, time and an assignable ID number and contain GLP-supporting data.

03
Waterproof housing, IP 67

The housing is rated IP 67 and the USB interface is waterproof.

04
Battery operation up to 100 hours

Runs on four AA or NiMH cells for up to 100 hours, or up to 800 hours without backlight.

Parameters

pH

pH

Range−2.000…19.999 pH
Range 1−2.0…20.0 pH
Accuracy 1± 0.1 pH
Range 2−2.00…20.00 pH
Accuracy 2± 0.01 pH
Range 3−2.000…19.999 pH
Accuracy 3± 0.005 pH
mV

Redox / millivolt

Range 1±1200.0 mV
Accuracy 1± 0.3 mV
Range 2±(2500 ±1) mV
ISE

Ion-selective electrode concentration

Range 10.000…9.999 mg/l, µmol/l, mg/kg, ppm, %
Range 210.00…99.99 mg/l, µmol/l, mg/kg, ppm, %
Range 3100.0…999.9 mg/l, µmol/l, mg/kg, ppm, %
Range 41000…999999 mg/l, µmol/l, mg/kg, ppm, %
κ

Conductivity

The lowest conductivity ranges depend on the cell constant of the conductivity cell connected.

Range0.000 … 1.999 µS/cm (only with cells of cell constant 0.010 cm-1) 0.00 … 19.99 µS/cm (only with cells of cell constant 0.010 cm-1 or 0.090 … 0.110 cm-1) 0.0 … 199.9 µS/cm 200 … 1999 µS/cm 2.00 … 19.99 mS/cm 20.0 … 199.9 mS/cm 200 … 1000 mS/cm
Accuracy± 0.5 %
T

Temperature

Range−5.0…105.0 °C
Accuracy± 0.1 °C

Consumables

These are the consumables this instrument uses. We confirm the part numbers for your instrument when we quote.

Standards & buffers

Calibration standards

Calibration standards, pH buffers and electrolyte solutions for calibrating the instrument.

Electrodes & spares

Electrodes & probes

Electrodes, probes and replacement sensors, matched to the instrument.

Specifications

Part number2EA310
Calibration memoryup to 10 calibrations
AutoReadautomatic/manual selectable
DisplayLCD graphic display, backlit
Data memorymanual 200/5000 automatic
Loggermanual/time controlled
InterfaceUSB 1.1
Power supply4 x 1.5 V AA or 4 x 1.2 V NiMH-rechargeable battery
Continuous operation timeup to 100 hours/800 hours w/o backlit
IP ratingIP 67
pH−2.0…20.0 ±0.1 pH −2.00…20.00 ±0.01 pH −2.000…19.999 ±0.005 pH
mV±1200.0 ±0.3 mV ±(2500 ±1) mV
ISE (mg/l, µmol/l, mg/kg, ppm, %)0.000…9.999 10.00…99.99 100.0…999.9 1000…999999
Temperature−5.0…105.0 °C ±0.1 °C
CMCyes
pH calibration1-, 2-, 3-, 4-, 5 point WTW Technical NIST and 20 additional buffer sets
ISE calibration2-7 point
Logging intervaladjustable between 1 s and 60 minutes
Inputs2 (DIN, 8 pin socket)
Conductivity0.000 … 1.999 µS/cm (only with cells of cell constant 0.010 cm-1) 0.00 … 19.99 µS/cm (only with cells of cell constant 0.010 cm-1 or 0.090 … 0.110 cm-1) 0.0 … 199.9 µS/cm 200 … 1999 µS/cm 2.00 … 19.99 mS/cm 20.0 … 199.9 mS/cm 200 … 1000 mS/cm
Conductivity accuracy± 0.5 % (no temperature compensation (off)) ± 0.5 % (non-linear nLF, 0 °C … +35 °C, per EN 27 888) ± 0.5 % (+35 °C … +50 °C, extended nLF function) ± 0.5 % (linear Lin, +10 °C … +75 °C)

Tags and applications

Brand
WTW

Downloads

Common questions

What does the WTW ProfiLine pH/Cond 3320 measure?

It measures pH, redox in mV, ion-selective electrode concentration, conductivity and temperature. It is suited to all modern WTW pH electrodes, combined ISE electrodes and conductivity cells.

Can it measure pH and conductivity at the same time?

Yes. It has two inputs (DIN, 8 pin socket) for simultaneous measurement of pH, mV or ISE and conductivity. The backlit graphic display shows the values in parallel.

How many readings can it store and how often can it log?

Data memory holds 200 manual records and 5000 automatic records. The logging interval is adjustable from 1 s to 60 minutes.

How is the meter powered and how long does it run?

It takes four 1.5 V AA batteries or four 1.2 V NiMH rechargeable batteries. Continuous operation is up to 100 hours, or up to 800 hours without backlight.

How do I transfer data to a computer?

Through the waterproof USB 1.1 interface. Records carry date, time and an assignable ID number.

What is the pH range and accuracy?

The pH range is −2.000 to 19.999 pH. Accuracy is ±0.1 pH, ±0.01 pH or ±0.005 pH, depending on the resolution range used.

Tell us what you need to measure.