Skip to content
Solution: TSS and CCTV monitoring with automatic intervention, for construction sites under Earth Control Measures.See how it works
Lovibond · Photometer / Colorimeter

MD 600

Use the Lovibond MD 600 to measure disinfectant residuals, hardness and alkalinity, nitrogen and phosphorus nutrients, metals, organic load, pH, turbidity and suspended solids in water samples. It runs more than 120 pre-programmed photometric methods using six LED wavelengths between 430 and 660 nm. It also accepts up to 35 user-defined methods for parameters the built-in list does not cover.

Pre-programmed methodsOver 120
Wavelengths430, 530, 560, 580, 610, 660 nm
Photometric accuracy2 % FS (T = 20 °C – 25 °C)
IP ratingIP 67
Power supply4 batteries (Mignon AA/LR6)
Internal storageApprox. 1000 data sets
Lovibond MD 600 photometer wet with water droplets, angled front view

Highlights

01
128 methods in six groups

Groups are disinfectants, hardness and alkalinity, nutrients, metals, organic load, and pH, turbidity and suspended solids.

02
Six wavelengths from 430 nm

Interference-filtered LEDs at 430, 530, 560, 580, 610 and 660 nm. Wavelength accuracy is ±1 nm.

03
IP 67 rated housing

The keypad is acid and solvent resistant. Stated operating range is 5 to 40 °C, non-condensing.

04
Up to 35 user-defined methods

You can create your own calibration curves and keep them alongside the pre-programmed methods.

Methods and ranges

The table shows 15 of the 128 methods. The full list covers chlorine and other disinfectants, hardness and alkalinity, nitrogen and phosphorus nutrients, metals, organic load (COD, TOC, TN), and pH, turbidity and suspended solids. Ask us for the complete method list for the parameters you need.

15 of 128 shown
ParameterRangeMethodReagent
Chlorine T0.01 - 6.0 mg/L Cl2DPDT
Chlorine dioxide T0.02 - 11 mg/L ClO2DPD / GlycineT
Ozone T0.02 - 2 mg/L O3DPD / GlycineT
COD LR TT3 - 150 mg/L CODDichromate / H2SO4TT
COD MR TT20 - 1500 mg/L CODDichromate / H2SO4TT
Ammonia LR TT0.02 - 2.5 mg/L NSalicylateTT
Nitrate TT1 - 30 mg/L NChromotropic AcidTT
Phosphate PP0.02 - 0.8 mg/L PPhosphomolybdenum BluePP
Iron PP0.02 - 3 mg/L Fe1,10-PhenanthrolinePP
Copper PP0.05 - 5 mg/L CuBicinchoninatePP
pH-value T6.5 - 8.4 pHPhenol RedT
Alkalinity-m T5 - 200 mg/L CaCO3Acid / IndicatorT
Hardness total T2 - 50 mg/L CaCO3MetallphthaleineT
Turbidity 2410 - 1000 FAUAttenuated Radiation Method
Suspended solids 2410 - 750 mg/L TSSTurbidity / Attenuated Radiation Method

Reagents & consumables

We keep these in stock for the MD 600. We quote part numbers per instrument on enquiry, checked against the current price list.

Reagents

Liquid reagents, Powder packs, Tablet reagents, Tube tests

Tablets, pre-measured powder packs, liquid reagents and sealed tube tests for the methods already programmed into the instrument.

Standards & buffers

Calibration standards

Calibration standards, pH buffers and electrolyte solutions for calibrating the instrument.

Cells & glassware

Cuvettes & sample cells

Round cells, cuvettes and caps.

Specifications

Part number214020
Pre-programmed methodsOver 120
OpticsLEDs, interference filters (IF) and photo sensor in transparent sample chamber
Wavelengths430 nm IF Δλ = 5 nm; 530 nm IF Δλ = 5 nm; 560 nm IF Δλ = 5 nm; 580 nm IF Δλ = 5 nm; 610 nm IF Δλ = 6 nm; 660 nm IF Δλ = 5 nm
Wavelength accuracy± 1 nm
Photometric accuracy2 % FS (T = 20 °C – 25 °C)
Suitable vialsMulti vial 10 mm; Round cuvettes 13 mm; Round cuvettes 16 mm; Round cuvettes 24 mm
DisplayGraphic-display
InterfacesInfrared
OperationAcid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper
Auto-OFFYes
UpdatesSoftware updates via internet
Internal storageApprox. 1000 data sets
Power supply4 batteries (Mignon AA/LR6)
Battery lifeapprox. 26 h
PortabilityLab and field
Environmental conditions5 – 40 °C at max. 30 – 90 % rel. humidity (non condensing)
IP ratingIP 67
ComplianceCE
User interface languagesGerman, English, French, Spanish, Italian, Portuguese, Polish, Indonesian
Dimensions95 x 45 x 210 mm
Weight450 g
User-defined methodsUp to 35

Tags and applications

Select any tag to see every other instrument that carries it. A tag with no link is one this line does not filter on.

Downloads

Common questions

What can the Lovibond MD 600 measure?

It covers chlorine and other disinfectants, hardness and alkalinity, nitrogen and phosphorus nutrients, metals, organic load (COD, TOC, TN), pH, turbidity and suspended solids. There are 128 methods in total.

How accurate is the MD 600?

Photometric accuracy is 2 % FS at 20 °C to 25 °C. Wavelength accuracy is ±1 nm.

Which vials and cuvettes does it accept?

It accepts multi vials of 10 mm, and round cuvettes of 13 mm, 16 mm and 24 mm.

How is the MD 600 powered and how long do the batteries last?

It runs on four AA (Mignon, LR6) batteries. Stated battery life is approximately 26 hours. It also has an auto-off function.

Can I add my own methods?

Yes. You can create user-defined calibration curves, with up to 35 user-defined methods.

Which reagents does each method need, and are they supplied with the instrument?

The method table lists the reagent type for each method, such as tablet (T), tube test (TT) or powder pack (PP). Whether reagents are included, and which to order for your parameters, depends on your application. Please ask us.

Tell us what you need to measure.

Send the parameters and ranges you need, and we will confirm the right configuration and price. Your enquiry will name this product.