Ebro · Infrared thermometer

TFI 54 / TFI 260 / TFI 550

The ebro TFI 54, TFI 260 and TFI 550 are non-contact infrared thermometers for surface temperature checks in settings such as food inspection, industry and trade. Each aims with a laser and reads from -60 °C, up to +550 °C on the TFI 54 and TFI 260 and up to +760 °C on the TFI 550. The TFI 550 adds a 30:1 distance:spot ratio and a socket for NiCr-Ni penetration probes.

Range-60 °C … +760 °Cvaries by version
Accuracy± 1 … ± 1.5 °Cvaries by version
Distance:spot ratio12:1 · 30:1varies by version
Emissivityadjustable · fixed at 0.95varies by version
IP ratingIP54 · IP20varies by version
ebro TFI 54 infrared thermometer seen from the front on a white display block, showing the display and buttons

Highlights

01
Non-contact infrared surface measurement

Each model reads surface temperature from a distance, from -60 °C up to +550 °C, or +760 °C on the TFI 550, with a laser for aiming.

02
Adjustable emissivity on TFI 54 and TFI 550

On the TFI 54 and TFI 550 the emissivity can be changed to match the surface. The TFI 260 is fixed at 0.95, which suits most foods.

03
Maximum, minimum, difference and average

The TFI 54 and TFI 550 offer maximum, minimum, difference and average modes, with high and low alarm limits.

04
Core temperature with the TFI 550

The TFI 550 has a socket for NiCr-Ni probes, which measure from -64 °C to +1400 °C.

Parameters

T

Temperature (infrared surface temperature)

Accuracy depends on the object temperature and the ambient temperature at the time of measurement.

Range-60 °C … +760 °C
Resolution0.1 °C in the lower range, otherwise 1 °C

Configurations

Every model is a non-contact infrared thermometer with a laser for aiming. They differ in range, distance:spot ratio, emissivity setting and probe connection.

1340-1754

TFI 54

Infrared thermometer; -60 °C to +550 °C; 12:1 distance:spot ratio; adjustable emissivity; single laser; IP54; 180 g including batteries.

1340-1755

TFI 260

Basic infrared thermometer for fast food inspection; -60 °C to +550 °C; 12:1 distance:spot ratio; emissivity fixed at 0.95; circular laser; always-on backlight; IP20.

1340-1786

TFI 550

Infrared thermometer; -60 °C to +760 °C; 30:1 distance:spot ratio; double laser; NiCr-Ni probe socket for core temperature, -64 °C to +1400 °C; IP20.

Probes

1343-0646

TPN 601

Exceeds DIN EN 60584 class 2, 1.9 x 1.2 mm outside, 1 m cable, SMP connection, -50 °C...400 °C

FitsTFI 550

Specifications

Measuring range, infraredTFI 54TFI 260-60 °C to +550 °CTFI 550-60 °C to +760 °C
Accuracy, object +15 °C to +35 °C at ambient 25 °CTFI 54TFI 260±1.5 °CTFI 550±1 °C
Accuracy, full rangeTFI 54TFI 260±2 % of reading or ±2 °C, whichever is greater, at 0 °C to +550 °C; ±(2 °C + 0.05 °C per °C below 0) at -60 °C to 0 °C; ambient 23 ±3 °CTFI 550±2 % of reading or ±2 °C, whichever is greater; ambient 20 °C to 26 °C
Probe measurement (NiCr-Ni)TFI 550-64 °C to +1400 °C; ±1 % of reading or ±1 °C, whichever is greater
ResolutionTFI 54TFI 2600.1 °C from -9.9 °C to +199.9 °C, otherwise 1 °CTFI 5500.1 °C from -64 °C to +999.9 °C, otherwise 1 °C
EmissivityTFI 540.95 default, adjustable 0.10 to 1.00 in steps of 0.01TFI 260fixed at 0.95TFI 5500.95 default, adjustable 0.1 to 1.0
Distance:spot ratioTFI 54TFI 26012:1TFI 55030:1
Response time (90 %)approx. 1 s
WavelengthTFI 5508 to 14 µm
LaserTFI 54single laser pointerTFI 260circular multi-beam laserTFI 550double laser pointer
Operating temperature0 °C to +50 °C
Storage temperatureTFI 260-20 °C to +65 °CTFI 550-20 °C to +65 °C, without battery
Battery2 x AAA, 1.5 V
Battery lifeTFI 54TFI 260typically 18 h, minimum 14 h of continuous useTFI 550typically 140 h without backlight
Automatic switch-offTFI 54TFI 260after 15 s idle
DimensionsTFI 54143.9 x 116.7 x 42.8 mmTFI 260114.8 x 162.2 x 40.0 mmTFI 55046.0 x 121.0 x 195.0 mm
WeightTFI 54180 g, including batteriesTFI 260179.2 g, including batteriesTFI 550approx. 282 g, including batteries
Housing materialTFI 550ABS
IP ratingTFI 54IP54 (splash proof)TFI 260TFI 550IP20
Maximum error in electromagnetic fieldTFI 545 °C under 3 V/m from 200 to 700 MHz
CertificateFactory calibration certificate TFI 54 · TFI 260: certificate at 0 °C

Tags and applications

Measured variable
Temperature
Thermometer type
Infrared
Brand
Ebro

Downloads

Common questions

What temperature range do the TFI 54, TFI 260 and TFI 550 measure?

The TFI 54 and TFI 260 measure surface temperature from -60 °C to +550 °C. The TFI 550 measures from -60 °C to +760 °C, and from -64 °C to +1400 °C with a NiCr-Ni probe.

Which ebro TFI model has the highest distance:spot ratio?

The TFI 550 has a 30:1 distance:spot ratio. The TFI 54 and TFI 260 have 12:1.

Can the emissivity be adjusted on the ebro TFI infrared thermometers?

On the TFI 54 and TFI 550, yes. The default is 0.95 and it can be adjusted from 0.1 to 1.0. The TFI 260 is fixed at 0.95.

Which ebro TFI model is splash proof?

The TFI 54 is rated IP54 and is splash proof. The TFI 260 and TFI 550 are rated IP20.

Can the TFI 550 be used with a penetration probe?

Yes. The TFI 550 has a NiCr-Ni connection for core temperature measurement with a penetration probe. It takes all NiCrNi probes with an SMP connector.

How long do the batteries last?

The TFI 54 and TFI 260 typically run 18 hours of continuous use, with a minimum of 14 hours. The TFI 550 typically runs 140 hours without the backlight.