Water Analysis

  • Online
  • Laboratory & Field
  • MD 100 Suspended Solids : Portable TSS photometer

    < Back

    measures up to 750 mg/l

    MD 100 Suspended Solids
    Portable TSS photometer

    For measurement of TSS (Total Suspended Solids)

    Brand: Lovibond

    Applications:

    • Silty Water (Earth Water)
    • Water Treatment
    • Wastewater
    • Drinking Water
    • Cooling/Boiler Water
    • Laboratory & Field Testing

    Features:

    • Range: 0 – 750 mg/l TSS
    • No reagents required
    • Waterproof
    • Automatic switch-off
    • Real-time clock and date
    • Calibration mode
    • Backlit display
    • Storage function
    • Suitable for use as a reference instrument

    The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparency sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions, and safe handling.

    Calibration certificate
    Beside the “Certificate of Compliance” which is supplied with the MD 100, calibration certificates are available at cost on request. Calibration certificates are individually supplied per instrument and per method. The Calibration Certificate has to be ordered together with the new instrument and cannot be delivered at a later stage.

    N.I.S.T Traceability
    The instrument has a factory calibration, which is related to international standards which are not N.I.S.T traceable. The instrument may be calibrated by the user in a “user calibration mode” with N.I.S.T traceable standards.
    (N.I.S.T. = National Institute of Standards and Technology)

    Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used.
    Wavelength specifications of
    interference filters:
    430 nm Δ λ = 5 nm
    530 nm Δ λ = 5 nm
    560 nm Δ λ = 5 nm
    580 nm Δ λ = 5 nm
    610 nm Δ λ = 6 nm
    660 nm Δ λ = 5 nm
    Wavelength Accuracy  ± 1 nm
    Photometric Accuracy 3% FS (T = 20°C – 25°C)
    Photometric  Resolution 0.01 A
    Power Supply 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests
    Power off automatic switch-off
    Display backlit LCD (on keypress)
    Storage internal ring memory for 16 data sets
    Interfaces infrared interface for test data transfer
    Additional feature real time clock and date
    Calibration factory calibration and user calibration. Reset to factory calibration possible
    Dimensions 155 x 75 x 35 mm (L x W x H)
    Weight basic unit approx. 260 g
    Environmental conditions temperature: 5 – 40 °C
    rel. humidity: 30 –90% (non condensing)